Low Pressure Duct Systems & Troubleshooting Techniques

  • 8 Hours

This course discusses and demonstrates the effect of proper and improper air flow in low pressure duct systems.  The student will observe and measure the change in motor amperage, external static pressure and cubic feet per minute when air is restricted within a duct system.  Basic fan laws will be introduced as well as information needed for both direct drive blowers and belt driven air movers.  This course will also cover some of the more common methods used in sizing ducts.  Troubleshooting an existing duct system will be used as the basis for covering this material.  This course is designed for the technician and installer who desires to know more about air flow and all of its effects in duct systems for residential and light commercial HVAC equipment.

 


Payment Policy

PAYMENT MUST ACCOMPANY REGISTRATION. We accept Visa, MasterCard, American Express, Check or Purchase Order. Make check payable to Trane.  Registrations are accepted on a first-to-register basis until the course is full. You will receive confirmation one (1) week prior to the Training session. If the course is already full, you will    receive notification immediately. It is the responsibility of the attendee to contact Trane if a confirmation is not received prior to the course date.

 


Directions & Nearby Hotels

From I-270 to the St. Louis Trane Office located at Trane 101 Matrix Commons Drive Fenton, MO 63026.  Take I-44 west to Bowles exit.  Turn left on Bowles and proceed to Horan (3rd stoplight).  Turn left on Horan.  Proceed on Horan to stop sign.  Continue straight ahead, the Trane office will be on the right side at 101 Matrix Commons Drive.  Enter building through Training Center entrance.

 

  • Drury Inn 1088 South Highway Drive Fenton, MO 63026 (636) 343-7822
  • Holiday Inn Express 1848 Bowles Ave. Fenton, MO 63026 (636) 349-4444
  • Drury Inn & Suites Southwest 5 Lambert Drury Dr. Valley Park, MO 63088 (636) 861-8300
  • Fairfield Inn 1680 Fenton Business Park Court Fenton, MO 63026 (636) 305-1500

 


Cancellation Policy

We realize that work schedules must be flexible. If your schedule changes you may request in writing by mail, fax, or email, a substitution for another course, or cancel your  registration, up to five (5) business days prior to the start of your scheduled course. Cancellations received at least five (5) days prior to the program are refundable. Substitutions & cancellations are subject to a $25 registration service charge. If you do not notify us in writing five (5) business days before the course, or don’t attend, you are still responsible for payment of entire course fee.  Course substitutions must be used within that year and cannot be rolled over to the next.  Dates listed are subject to change based on instructor availability. We will notify you in advance if this happens. We reserve the right to cancel any course if minimum course size is not obtained. In the event of a cancellation, you will be contacted regarding a new date or your money will be refunded in full. Our liability will be limited to the return of the registration fee.


Locations & Dates