On-site Training

Air Conditioning Clinic

  • 2 Day Course 8:00am to 5:00pm each day
  • PEUS = HVAC 6.0 Trade, Pipefitter 6.0 Core, Sheet Metal 6.0 Core, Sprinklerfitter 6.0 Core

The course is a comprehensive battery of 15 sessions designed to give an overview of air conditioning fundamentals and associated systems.  Each session deals with a specific area of the many disciplines required to successfully design and install air conditioning equipment.  Upon completion the attendee will have a better understanding of the various equipment and systems used in providing comfort cooling today and be able to identify the individual components and their operation.  Booklets on the topics are provided for the attendee to do further study.

Topics include:  Air handler systems, psychrometry, heat load estimation, refrigeration system components, refrigerant piping, absorption chillers, centrifugal chillers, helical-rotary chillers, fans, VAV systems, HVAC controls, chilled water systems, water source heat pumps and ice storage systems.  Each student receives a manual having the clinic presentations ($200 value).

Course Instructor:  Elmer Franklin

 


Payment Information

PAYMENT MUST ACCOMPANY REGISTRATION. We accept Visa, MasterCard, American Express, Check or Purchase Order. Make check payable to Trane.  Registrations are accepted on a first-to-register basis until the course is full. You will receive confirmation one (1) week prior to the Training session. If the course is already full, you will receive notification immediately. It is the responsibility of the attendee to contact Trane if a confirmation is not received prior to the course date.

 


Cancellation Policy

We realize that work schedules must be flexible. If your schedule changes you may request in writing by mail, fax, or email, a substitution for another course, or cancel your registration, up to five (5) business days prior to the start of your scheduled course. Cancellations received at least five (5) days prior to the program are refundable. Substitutions & cancellations are subject to a $25 registration service charge. If you do not notify us in writing five (5) business days before the course, or don’t attend, you are still responsible for payment of entire course fee.  Course substitutions must be used within that year and cannot be rolled over to the next.  Dates listed are subject to change based on instructor availability. We will notify you in advance if this happens. We reserve the right to cancel any course if minimum course size is not obtained. In the event of a cancellation, you will be contacted regarding a new date or your money will be refunded in full. Our liability will be limited to the return of the registration fee.

 


Locations & Dates